#2
|
||||
|
||||
|
Your set probably uses an STR regulator . Lets use an STR 30130
as example. The 130 means it is a 130 volt regulator. ( the also come in 30123, 30125, 30135. etc). Near the STR there is a BIG resistor. One side is apx 150 VDC the other is 130 VDC. That voltage should stay the sam from no raster to full brightness. Now if you have a Variac hang you meter on the 130 V end of resistor & run the set from 100 VAC to 135 VAC It should be a constant 130 V. If either tests fail you MAY have a power supply problem. Nature of the beast is also possable. Low price sets have simpler designs, are a generation or 2 behind, & overall quality is lower than the higher end sets. Thats why some sets can get NTSC stations on rabbit ears up to an easy 150 miles & others wont see it at all. 73 Zeno ![]() LFOD ! |
|
|