Quote:
Originally Posted by Tubejunke View Post
The problem that I have is that wax paper, or basically non electrolytic caps work fine on the DC leakage tests. But when I connect any electrolytic to the unit there is no reaction at all on the shadow angle of the "magic eye" tube. I have read that electrolytics can be more difficult to test on these units; and I know that the charge time is longer, but I could hold the leakage switch 10 min and get no reaction. I can take any of my test caps to my Heathkit IT-28 and get quick results.
Are you indicating that the eye never closes or never opens? Im confused.

Have you measured the voltage applied to the capacitor check terminals during leakage tests at all set voltages and both modes (paper/mica and electrolytic) ?