#1
|
|||
|
|||
|
clearing G1 Shorts
Working on a set with a shorted G1 per the sencore CR-70 (no control over brightness fixed and too much brightness).
I followed the directions, checked after each try, max of 3 tries, no improvement. Any tips? Its a very nice set (this is the one near Disney that TVdude1 was asking for someone in the area to check on. its a 21CEP4. the set is MINT!! older RCA upright, did not not the model but looks just like a mini version of my CTC-9 |
|
#2
|
||||
|
||||
|
Must be a bad short, try a tester with a higher power short clearing function. Or discharge a 3000uf 150v cap through it.
__________________
Evolution... |
|
#3
|
|||
|
|||
|
I was thinking about something like that but afraid it may burn a connector (of course the tube no use now anyway). I was going to try it again, but this time with the face of the tube down and tapping the neck as I hit the button. I was getting a good arc so something was happening, but it did not clear on the 1s few trys. I do not have the set currently but the owner said he would bring it back so I can try again.
|
|
#4
|
||||
|
||||
|
The CR70 is known for being gentle, that's why you should try one that's not. The B&K testers seem to have a cap discharge short clearing function, do you have one of those? I can't remember the value of the cap in my 466, but it was around 400 volts I know that much.
__________________
Evolution... |
|
#5
|
|||
|
|||
|
I think I have a 440 somewhere out in the garage, stopped using it when I got the Sencore
|
| Audiokarma |
|
#6
|
||||
|
||||
|
You have nothing to lose really, the tube doesn't work anyway.
__________________
Evolution... |
|
#7
|
|||
|
|||
|
Got the 440 out, checked the caps, had an old partially shorted 5mf 250v, replaced that, used it to check some of my tubes seems to be working, so will use in on the 21CEP4 when it comes back in to the shop.
|
|
#8
|
|||
|
|||
|
I have a fairly good book on this. Ill have to read up on it. My question is what is g1 shorted to? G2 or the Cathode? I would hate to blow that little think cathode wire open. From what you told me about the set I bet it was a factory defect and a customer return.
Maybe you could ask Timmy if he has any tips on clearing the shorts...? |
|
#9
|
|||
|
|||
|
routine short cleaning maint 101
|
|
#10
|
||||
|
||||
|
Quote:
Speaking of shorts, a cathode to filament one would be worse as you can't clear those. However, with the use of a Brightner/Transformer they can be isolated. You should be able to clear yours. |
| Audiokarma |
|
#11
|
|||
|
|||
|
Hmmm, my Sencore book says G1 to G2, it turns the filament off and removes it from the circuit to protect it.
It also says bang away, if there are sparks there is hope. No sparks indicate a mechanical short. |
|
#12
|
||||
|
||||
|
Quote:
|
|
#13
|
||||
|
||||
|
Wow...I know you mentioned about laying the set on it's face, but something must have lodged itself good to cause a short like that. Yes, sparks are good but I'd also consider putting the set upside down, sideways etc. in your attempts!
|
|
#14
|
||||
|
||||
|
Quote:
good day
|
|
#15
|
||||
|
||||
|
oh and yes i agree isolating the short would be a great idea, what do you think ctc17? oh and if its a cathode to filiment short..................................
Last edited by timmy; 07-06-2012 at 01:08 PM. |
| Audiokarma |
![]() |
|
|