Quote:
Originally Posted by pac.attack76
Lead change?
|
Yes, you remove the red lead from the V, diode, ohm hole and move it to the ammeter side. Depending on your meter, it may have one or two holes for the ammeter side - one low (like below 400ma typically) and a higher one for several amps or more.
The black lead stays put.
John
EDIT: make sure to remove the lead from the ammeter hole when done as it presents essentially a dead short across the leads and you don't want to measure voltage in that manner.