#11
|
||||
|
||||
|
By convention use the steel chassis for ground ( - or black lead).
Newer sets may have several ground points. Voltage is measured at the Hoz out tube G-1 (6LB6 ? ). If the voltage in NOT very negative ( @ -70 to - 90 VDC ) it will eat the H out & in some cases melt it ! So keep testing under 1 mn til you get a raster. You can measure from the top, you just need to count the pins CCW. Pin out is on any data sheet for the tube. Zeno
|