#11
|
||||
|
||||
|
I assume you want to pull the chassis out ? Usually
you can flip it on edge & run it. Just dont put strain on the wires. Can usually put a box behind the set to rest it on. Alternitive is flip the whole set on its side HV area down & you can run it & do tests. Sets with bottom plates like Zeniths are almost always done that way. Just remember the purity will be way off, thats normal. One other important thing. Until you change the thermistor JUMP IT OUT or the VDR will burn. They stink too !!! On HV shocks be as careful as you wish. If you are healthy it should not harm you but....... I have got nailed many times by HV. Worse it did was give me A-fibs for maybe 20 sec. a few times. In fact if you already have A-fibs it may cure them if the timing is right ! When they fix them they put a ground on your back then on your chest. The machine has a sync curcuit & at the right point SNAP ! And you are back to normal rhythm often. You are asleep during it. I had it done 3 times. 73 Zeno
|