#1
|
||||
|
||||
|
Quote:
Second - to discharge the anode lead on the CRT - I use a grounded (chassis connected) clip lead attached to a long bladed screwdriver to discharge the CRT, then let it set for a few minutes and repeat. Then I grasp the 2nd anode rubber cup where the wire enters the cup and twist slightly, with some force to one side to dislodge the legs of the anode connector. Remember -the CRT is what is charged (its a big capacitor with plates of aquadag and a dielectric of glass), and will obtain a "surface charge" just sitting, so always discharge the anode button to the aquadag before doing anything around the CRT.
__________________
Brian USN RET 22YRS (Avionics/Cal) CET-Consumer Repair and Avionics ('88) "Capacitor Cosmetologist since '79" When fuses go to work, they quit! |
|
#2
|
|||
|
|||
|
Quote:
Hoooo... nope nope nope nope nope! If I have to I'll leave the wire connected and work around it instead. |
|
#3
|
||||
|
||||
|
Quote:
Do what you are comfortable with - Safety first. The discharge procedure is pretty much standard - RCA wanted a 56K resistor in series with the ground, but later made a discharge tool - basically a HV probe with a pushbutton discharge button. As long as the 2nd anode lead is connected, the cathode of the HV rectifier has juice on it, and still poses a danger if you are working near it. I've been bit a dozen times and never had any ill effects - just an adrenaline kick and a few choice words.
__________________
Brian USN RET 22YRS (Avionics/Cal) CET-Consumer Repair and Avionics ('88) "Capacitor Cosmetologist since '79" When fuses go to work, they quit! |
![]() |