#1
|
||||
|
||||
|
25Hz TV's
I mentioned in another thread about the humongous power transformers some early Canadian TV's had. Toronto was 25 Hz up until about 1952. Hence the power transformers they employed were pretty big.
I spotted on the Toronto Craigslist a Toronto made Motorola set. The rear view of the set is interesting: there appears to be an outboard power transformer located at the bottom rear. You can make out some heavy cabling going from the transformer to the chassis. I recall some older Canadian sets assembled from a US chassis which had transformers too big for the chassis. But I do not recall seeing the transformer mounted elsewhere. http://toronto.en.craigslist.ca/tor/atq/2691715215.html |
|
#2
|
|||
|
|||
|
Quote:
The owner of a TV shop in our town (Globe) was so impressed with the rig that he offered me a job which became the gateway to a lifelong avocation. Some kinda interesting notes on the Salt River hydro system.. https://www.srpnet.com/gallery/trd/1971.aspx http://www.usbr.gov/projects/Project...+River+Project Last edited by old_coot88; 11-17-2011 at 03:42 PM. |
|
#3
|
||||
|
||||
|
A 25 Hz motor wouldn't work on 60 Hz, but I see no reason why a 25 Hz
TV would not. Many 25 Hz Canadian TVs would have an extra series choke. |
|
#4
|
|||
|
|||
|
An exception would be a 'universal' or brushed motor such as used in vacuum cleaners, SkilSaws, hand drills etc. It would run on 25 or 60 cycle, or equally well on DC (that was before solid state speed controls on power tools).
Quote:
Quote:
Last edited by old_coot88; 11-17-2011 at 02:05 PM. |
|
#5
|
||||
|
||||
|
Interesting thread. I was under the impression that 25-Hz TVs were a Canadian
only affair, but I understand some US areas also had 25-Hz into the TV era (which obviously began earlier in the US). Someone mentioned Toronto in Canada had 25-Hz until about 1952, that just happens to be the year TV began in Canada. Areas in Quebec (Gaspesia) had 25 Hz until about 1963. I have seen pictures of fridges being fitted with replacement compressors in that region (that was when a fridge was considered a durable appliance...). |
| Audiokarma |
|
#6
|
||||
|
||||
|
I have a few Stromberg-Carlson radios with holes stamped in the chassis for 25 cycle xfmrs. I believe some areas around greater Buffalo NY used 25 cps into the 50s or later. The 25 cps rail road power plants in Cos Cob CT were dismantled maybe 15 or so years ago. I remember seeing flatbed trailers with HUGE transformers on them headed to the scrap yard.
__________________
stromberg6 |
|
#7
|
||||
|
||||
|
Quote:
The parking lot at Lansdale is next to a substation. Those transformers don't hum, they rumble... |
|
#8
|
|||
|
|||
|
Quote:
Our shop was LT Radio & TV Service. Darndest thing, Google Street View goes through that town, and the building is still there and virtually unchanged after 50 years. It's a baby goods and infant wear store now. |
|
#9
|
||||
|
||||
|
I used to live in Arizona and I never thought of Globe as a hick town! I do remember the copper mine!
And I never knew that Arizona used to have 25Hz power! This is very interesting information: I wonder besides canada and Arizona where else was 25Hz? I wrote the guy selling the TV in Toronto and he sent some more pictures. The transformer mounting seems odd mounted on what appers to be a wood slab. However it does look original. Note that the note refers to "Her Majesty". That means Elizabeth II was on the throne. My TV is a bit older and says "His Majesty" (George VI, her father). George VI died in February 1952 hence the set must have been made after then. I wonder when the licence notice was dropped from Canadian TV's? Here are the pictures so you can see for yourselves. Last edited by Penthode; 05-18-2026 at 09:22 AM. |
|
#10
|
||||
|
||||
|
Quote:
The last sentance I find freaking hilarious!
__________________
Tom C. Zenith: The quality stays in EVEN after the name falls off! What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4 |
| Audiokarma |
|
#11
|
|||
|
|||
|
Quote:
I guess Globe's only a hick town compared to major metro areas.Quote:
Last edited by old_coot88; 11-17-2011 at 10:16 PM. |
|
#12
|
||||
|
||||
|
Quote:
However a 25 Hz induction motor will definitely run on 60Hz although it will be 2.4 times faster. You definitely cannot run a 60Hz induction motor on 25 Hz power because it doesn't have enough iron and windings and will over heat immediately. Cliff |
![]() |
|
|