You can do a check on HV regulation by measuring the voltage drop on the 1000 ohm resistor on the 6BK4 tube cathode. The tube should be drawing about 1000 microamperes with the brightness all the way down which equates to 1 volt drop across the resistor (caution: both ends of the resistor are at 400 volt potential). The SAMS should state the exact current draw on the 6BK4 for this set.
If the voltage is around 1.5 volts or more the tube is drawing too much current and HV is probably low; the HV control may need to be adjusted so the tube is drawing less current...if the voltage is only around 0.3 volts-0.5 volts either the 6BK4 tube is weak or someone has adjusted the HV so the HV is too high.
The focus rectifier diode is usually a selenium diode I believe, made up of a string of selenium pellets inside a ceramic tube. A 1n4007 diode cannot take the 5Kv or so on the focus system and will likely short...you would need to replace with a diode designed for this purpose. For the best diagnosis of HV and focus problems an HV probe will be a good idea.
Also check into a weak horizontal output tube causing weak HV and focus.
Worn tube sockets on circuit boards are the result of heat from tubes traveling downward and burning or cracking the plastic or phenolic the socket is made of. You can replace these by breaking up the burned material with diagonal cutters, desoldering the old pins, then soldering buss wire to the pins of a new good quality socket, and running the buss wire through the holes on the circuit board, to the next connection point on the trace that would have gone to the old socket.
Last edited by Chad Hauris; 07-29-2005 at 09:52 AM.
|