Videokarma.org

Go Back   Videokarma.org TV - Video - Vintage Television & Radio Forums > Early Color Television

Notices

We appreciate your help

in keeping this site going.
Reply
 
Thread Tools Display Modes
  #1  
Old 01-18-2015, 09:23 PM
DaveWM DaveWM is offline
VideoKarma Member
 
Join Date: Feb 2009
Location: Orlando FL
Posts: 5,607
Quote:
Originally Posted by Username1 View Post
Sounds like you nailed it !
I don't remember anything about sparking....
Fingers still crossed.....

.
That came up in conversation, after I told him to try a working tube from another set. He has the cover off so it can be seen, which may have gone unnoticed before if it was just installed with the cover in place. This is why long distance diagnosis is so hard. Its nearly impossible to cover all the bases. But to his credit he did note it and report back, with out that little nugget I would not have thought to check it. The knowledge of how a working regulator tube looks is kinda hard to describe, which is why I wanted him to look at one in a good set. So while powering up the bad set he was looking for the correct operation.
I just really really hope this turns out to be the problem.
Reply With Quote
  #2  
Old 01-19-2015, 08:25 AM
timmy's Avatar
timmy timmy is offline
VideoKarma Member
 
Join Date: Jan 2011
Location: Delaware ny
Posts: 3,719
ok the .12 cap that i replaced was in question as to what values i put together to make the .12 , so here it is .1- 630v and a .022- 630v in paralle. ok now on to the voltages, pin 1- 6bk4 to ground 407 v maybe the grid here was up a bit at the outlet, pin 2- to ground 94 v . pins 1&2 - 315 volts and pins 1&7 - 315 volts at first start up this 315 was 330 volts but then dropped. each filiment wire to ground was 94 volts so after checking these voltages i did not go into the other set to compare because if this voltage is to be under 225 volts then clearly those resistors must be a problem and i will have to check them. the 180k and 150k thats next....
Reply With Quote
  #3  
Old 01-19-2015, 08:55 AM
Username1's Avatar
Username1 Username1 is offline
Not sure how I got here.
 
Join Date: Dec 2009
Location: Orange County NY
Posts: 3,668
Yah, doing the math, should be around 180v give or take tolerances....

.
__________________
Yes you can call me "Squirrel boy"

Last edited by Username1; 01-19-2015 at 09:00 AM.
Reply With Quote
  #4  
Old 01-19-2015, 10:15 AM
DaveWM DaveWM is offline
VideoKarma Member
 
Join Date: Feb 2009
Location: Orlando FL
Posts: 5,607
I just pulled the back of mine, 177v pin 2 to ground about -210 pin 2 to pin 1.

I am posting up a very short video, should be there soon. I will leave the set out in case Timmy gets the HV working and has focus issues, I can look at how I have mine setup.

my video ran out before I could get the pin 2 to ground but I do show the 2 to 1 DC voltages.

Last edited by DaveWM; 01-19-2015 at 10:24 AM.
Reply With Quote
  #5  
Old 01-19-2015, 10:27 AM
DaveWM DaveWM is offline
VideoKarma Member
 
Join Date: Feb 2009
Location: Orlando FL
Posts: 5,607
https://www.youtube.com/watch?v=ALle...ature=youtu.be

here you go timmy
Reply With Quote
Audiokarma
  #6  
Old 01-19-2015, 10:48 AM
timmy's Avatar
timmy timmy is offline
VideoKarma Member
 
Join Date: Jan 2011
Location: Delaware ny
Posts: 3,719
well i got a problem here the 150 k and the 180 k i had already put resistors in series awhile ago and the 150 tests at 156k and the 180k tests at 182k so im looking for maybe a mistake on the 400v source or the 390v source maybe i crossed one of those sources. i just cant believe this crazyness. i need a smoke first.
Reply With Quote
  #7  
Old 01-19-2015, 10:58 AM
DaveWM DaveWM is offline
VideoKarma Member
 
Join Date: Feb 2009
Location: Orlando FL
Posts: 5,607
if the resistors check out you will need to go back to where they connect up.

the 180k goes to B+400v check there with meter, then check where the 150k goes to ground should be 0v there, then check the junction, should be +180v there. has to be.

if you replaced the resistors you need to make sure you connected up to the correct location, esp the B+ side. During our talk IIRC you said it was connected to the output of the 1s diode of the doubler, that is NOT where the 400v is but more like where the 200v is. the 180k goes to where the 400v is.

if you have it hooked up right (180k to 400v) and the junction is still around 90v, it would mean you have a leak to ground somewhere, disconnect the wire at that junction and check the voltage at the junction of the two resistors again, if it pops up to 180v from the 90v then..

perhaps that .1+.022 cap. if this is the case try disconnecting the .1+.022 cap (lift the ground side) and check the voltage again.

Last edited by DaveWM; 01-19-2015 at 11:06 AM.
Reply With Quote
  #8  
Old 01-19-2015, 11:13 AM
timmy's Avatar
timmy timmy is offline
VideoKarma Member
 
Join Date: Jan 2011
Location: Delaware ny
Posts: 3,719
ok i changed the resistors here and one end 180k starts at the diode and confirmed 400v , then goes to a tie strap and then the 150k from the tie to ground its all in the right place.
Reply With Quote
  #9  
Old 01-19-2015, 11:17 AM
timmy's Avatar
timmy timmy is offline
VideoKarma Member
 
Join Date: Jan 2011
Location: Delaware ny
Posts: 3,719
what junction, the filiments to ground ? so at this point it could be any cap from a positve source to ground causing the filiment voltage to be hi or am i off here.

Last edited by timmy; 01-19-2015 at 11:22 AM.
Reply With Quote
  #10  
Old 01-19-2015, 11:22 AM
DaveWM DaveWM is offline
VideoKarma Member
 
Join Date: Feb 2009
Location: Orlando FL
Posts: 5,607
disconnect the wire that connects to the junction and so all you have is the two resistors in series, then read the voltage at the junction.
Reply With Quote
Audiokarma
  #11  
Old 01-19-2015, 12:11 PM
DaveWM DaveWM is offline
VideoKarma Member
 
Join Date: Feb 2009
Location: Orlando FL
Posts: 5,607
more from Timmy

with the voltage divider in place but not attached to the filament he get 180v
attaching the filament drops it to 90v, not right.

the filament string reads infinite with a ohm meter (disconnected from the voltage divider) yet when connected drops the voltage.

I advised Timmy to disconnect the .1 cap, as its the only thing that is connected to ground and the filament. The cap replaced but could be the issue if it leaks when voltage is applied. I assume Timmy used a 630v cap for the replacement. FYI I always check new caps going in for value AND leakage at rated voltage.

Timmy understands that the voltage at the 180k/150k should be 180vdc and SHOULD NOT DROP when the filament wiring is attached. All the test where conducted with the shunt tube out of the socket.

Timmy please confirm the above esp the test were conducted with the shunt tube out of the socket (and I hope the horz out tube out also, so you dont have to worry about HV being produced).
Reply With Quote
  #12  
Old 01-19-2015, 12:34 PM
DaveWM DaveWM is offline
VideoKarma Member
 
Join Date: Feb 2009
Location: Orlando FL
Posts: 5,607
more updates

further looks at the schematic shows the same filament supply goes to other tubes with elevated cathodes, the CRT and the second IF tube.

thinking maybe a HK short, the CRT is not connected, so he pulled the 2nd IF still dropping the 180v to 90v.

.1 cap off shunt to ground, disconnected no help.

Timmy will trace all wires, disconnect one at a time until 180v is restored and the dropping point is isolated. I did see a couple dog bone caps on the IF strip, grounding that 2nd IF tube filament. So maybe disconnecting the IF H1/H2 (2nd IF heater)supply may be a easy place to start.


Realizing the CRT is at risk (of a HK short) , I think I will routinely check the DC potential of all my set, just in case of some drifting of that voltage divider.
Reply With Quote
  #13  
Old 01-19-2015, 01:09 PM
Username1's Avatar
Username1 Username1 is offline
Not sure how I got here.
 
Join Date: Dec 2009
Location: Orange County NY
Posts: 3,668
C 309 and C 310 up there filaments to ground at the IF tube also.....

Yah, don't pass on the thought that it could be an internal tube short... I chased one
of those once, refused to believe a tube could do that... Also crud or a wire or something
actually on any of the tube pins, or socket, top or bottom.... Maybe that set is haunted... Cursed....


-WOW- This problem is a real Hum-Dinger !

.
__________________
Yes you can call me "Squirrel boy"
Reply With Quote
  #14  
Old 01-19-2015, 01:29 PM
DaveWM DaveWM is offline
VideoKarma Member
 
Join Date: Feb 2009
Location: Orlando FL
Posts: 5,607
Timmy
c309 and c310 are the sams c25 and c26 those are the two dog bones we discussed.

SB is using the RCA numbers from the rca schematic.
Reply With Quote
  #15  
Old 01-19-2015, 01:45 PM
DaveWM DaveWM is offline
VideoKarma Member
 
Join Date: Feb 2009
Location: Orlando FL
Posts: 5,607
PROGRESS!!
c26 (C310) burned to a crisp, a likely source of leakage due to carbonization.

he is going to replace and hook all back up, retest pin 1 and 2 of shunt to see if down below max of 225 (was 310).

if that is the case then should be safe to try a good shunt without fear of HK breakdown.
Reply With Quote
Audiokarma
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 05:55 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.