#1
|
|||
|
|||
|
looking very good now. Just have to check the HOT cathode current. Screen current is right on the nose at 18ma, grid voltage is -62v. I found two bad disk caps on was the coupler cap to the grid of the HOT
and the other looked like a HOT screen decoupler, both brown disk. The grid cap would barely open the eye, the decoupler would open it about 1/2 way. Both were toasted somewhat by a large 5watt resistor (literally), they had brown burn spots on them. I replaced the grid cap with a 1kv dipped film cap and the bypass with a 630v .01 yellow tube cap. I am suprised the grid cap worked as well as it did. there is a .001 1kv disc cap off the plate of the horz discharge tube. Guess I should check it out as well. Its a 10% and I think it is related to the amplitude of the horz pulse from the discharge tube. I am still trying to get the PP up to 250v, its about 200v now.
|
|
#2
|
|||
|
|||
|
had to clip out the .001 1kv disc to test, tested fine for cap, maybe a little low value, no leakage at 450v (as high as I can go), replace it with a .001 1kv just to be sure. Still can't get the PP any higher at the plate of the horz discharge. getting tired. I will check the HOT current tomorrow, will also try swapping out some other 6U10's to see if that makes any diff. Over all the pic is looking good, have not touched purity or convergence, but could watch it the way it is. Still need to check the remaing can caps.
|
|
#3
|
|||
|
|||
|
One more an open 10 uf decoupling cap in the audio section. geez this this has a lot of bad cans, worst I have seen in a zenith.
|
|
#4
|
|||
|
|||
|
Dave is self talking, may have combo complex.
|
|
#5
|
|||
|
|||
|
whew, just about there. I restuffed one of the caps (3 section, 2 of them were open) this cleared up the audio problem (the audio not coming in except when the fine tuning was into herring bone interference on the video). the audio fine tuning is very broad now.
The poor details on fine print turned out to be the video peaking, I had it turned down all the way. It needs to be about mid point too much and it looks like ringing in the video, too little and I lose fine detail. Guess that is the way its supposed to be. I recall reading somewhere it was used to compensate for the broadcast of the day. I checked the other 4 section check ok, power factor of about 10-15 to open the eye, but that was on 4uf 475v sections, and IIRC even new caps need some power factor adj to fully open the eye on low values like that. The double caps were replaced at some point, and test ok so I will leave them alone. AGC voltage had a bit of 60hrz about 100mv not sure what that is about, I think I will check some tubes in the AGC circuit and see if there is a short in there. It did not have any horz freq hash so and seems to be working just fine. I adj the pin cushion, very good now, and the form looks exactly as it should. The B+ has about 2v of ripple. looking good, have to set up for purity. |
| Audiokarma |
|
#6
|
|||
|
|||
|
one last thing, I was setting up the votage calibration on my scope by setting the .5v square wave from the scope test point to 500mv to be 5 divisions (one full box). then when testing the PP on say the Horz drive, I would switch to 10x and 10v. I got to thinking that maybe this was adding up minor inaccuracys so I went back and set it up by using the 10v at 10x DC mode on the 350v B+ (verified with a DMM). I reset the scope to AC mode and then read the Horz drive 240v PP. The sams had it at 250v so I figure I am good and perhaps some of my earlier readings where just scope calibration problems. Live and learn. For now on I will try to calibrate the scope with a test voltage near the voltage I want to check.
|
|
#7
|
|||
|
|||
|
there was some audio signal in the video, I tweeked the 4.5mhz trap to minimize it. One of the converg board coils is stripped so its a bit iffy on holding the blue horz right. I may try the thin rubber band in the coil trick.
I get about 220ma at 117vac. it will go to 250 at the normal line voltage of 125vac. I have been toying with the idea of adding a term strip that would let you select differnt HOT screen voltages. On one of my zeniths (20YC138 IIRC) there is a jumper that lets you select different screen voltages so you can use different HOT's, seems like a good idea that may work for high line voltage. HV seems good, very little fluctuation. I did a purity setup and a convergence (as well as I could considering the loose coil). Soimeday I may attempt a cat removal, its not that bad, so it not high on the agenda. |
|
#8
|
|||
|
|||
|
after a slight detour due to some color bar bleeding issues, the set is really coming along. swapped out some demodulator tubes and its looking very good, before it did not like modern programing with all the hard edges etc... but that is better now. I still have a persistant ringing, show up on text and other hard lines, I will check the IF tubes again, but not sure where to look next for that.
|
![]() |
|
|