#1
|
||||
|
||||
|
Here's the wires on the small 14-pin color socket:
1 Brown (Heater) 2 Yellow/Red (Red Cathode) 3 Red (Red G1) 4 n/c 5 n/c 6 Yellow/Green (Green Cathode) 7 Green (Green G1) 9 n/c 11 Yellow/Blue (Blue Cathode) 12 Blue (Blue G1) 13 nc 14 Brown (Heater) Pins 8 and 10 do not exist on this socket. My harness also has a small 8-pin B&W socket: 1 Violet (Heater) 2 Green (G1) 3 n/c 4 n/c 5 n/c 6 n/c 7 Yellow (Cathode) 8 Orange (Heater) My harness does not have the socket shown in your last photo.
__________________
Sean - WØKPX |
|
#2
|
|||
|
|||
|
I finally got around to messing with the Beltron again. I gave up on the small color adapter it's too hacked up. Atleast I can use the other 2 sockets. The next problem is, when I plug it in thebshorts light is constantly flickering, and the heater voltage is pinned at 15 volts, the rheostat has no effect. I assumed because of age the caps might be going out. I opened it up and whoever worked on it was a savage. They replaced one of the caps, and fried the associated traces and jumped them with wire. I replaced both 150uf caps and re soldered as many joints as I could. Then I noticed one of the light bulb sockets was broken. I tried to solder it back together but when when I turned it on the light started flickering and sizzling, one of the ceramic resistors started to smoke. I quickly unplugged it. I let it cool and checked the resistors the good news is they're 1000 ohm resistors and they all track at about 998. The next thing I did was check the voltage coming out of the caps one is 167 volts the other is 365 I think, I have to recheck it. The next thing I did was try to check the diodes. I checked the two rectifier diodes but I didn't remove them from the circuit board, one tested like a diode should the other one seemed open. Then I checked the diode that goes to the very first gauge that one also tested as if it was open. I'm wondering if this would be causing all my trouble. Does anyone have a schematic for this? The only thing I was able to find was a hand drawn one and I'm not sure how accurate it is. According to the drawing the main power diodes are 1N4005, I happen to have some 1N4007's on the bench Can I use them to replace them? I haven't been able to read the one on the gauge I'm going to desolder it and check, but it looks much heavier Duty than the two for the power rectifying. I did check and clean the wire wound pot, it actually reads very well between two ohms and 24 ohms so I don't believe that's the problem. I also dug through my spare parts and found a socket that looks just like the original and replaced it so at least the light socket is no longer a problem
Last edited by Aperna1985; 01-24-2025 at 07:03 PM. |
|
#3
|
||||
|
||||
|
The filament control is wired as a rheostat. Unless you have a load connected, you will have full voltage indicated on the meter. I always turn the filament control fully CCW before connecting to a CRT. Then I advance the control CW until I get the proper filament voltage reading on the meter.
1N4007 diodes will work just fine to replace 1N4005. Both are rated 1A. 1N4005 is rated 600V PIV. 1N4007 is rated 1000V PIV. The power supply is a half-wave voltage doubler. The voltage output will be about twice the peak voltage of your AC line voltage. The schematic you are referring to is probably the one I drew up for my unit. Judging from the build I would not be surprised if there are differences between units.
__________________
Sean - WØKPX |
|
#4
|
|||
|
|||
|
Quote:
By any chance was your unit wired point to point or was it on a circuit board? Mine follows your diagram perfectly except it has a 10ohm ceramic resistor between the negative of the 150uf 150v cap and the feed for the resistors. It looks like someone added it but I'm not 100% sure. My unit has a circuit board inside, and I notice there isn't a trace to and from the resistor but it was soldered in to the other traces. Could it be a last minute revision? Like I said previously someone was definitely in there before, he burnt a few traces that I fixed, and he wired the rejuvenate bulbs in series instead of parallel like it shows in the drawing. I went around and checked for AC and DC on pins 3 4 and 5 of the cleaning terminals, and the testing terminals and got nothing. Pins 3,4,and 5 of the restore connection all had 335v on them. The interesting part is I hooked it up to my TV which is a black and white set and I got a reading on the green gun only, the meter went about a quarter of the way up for emissions. I was able to control the heater voltage without any trouble once I hooked it up to the TV. I tried it in the cleaning position but none of the lights lit, and then I tried it in restore and the blue lights flickered for a second and that was it. Also my shorts light is always on. I hooked up my BK 465 and the emissions were the same as before trying the Beltron so it didn't do anything. Last edited by Aperna1985; 02-02-2025 at 09:37 PM. |
![]() |