#1
|
||||
|
||||
|
I should give an update! After completing my yearly recurrent training I was able to dedicate time to troubleshooting the horizontal section. Symptoms were horizontal off frequency, low HV.... and it caused TWO 6CG7's to short out internally.
I took three micamold style caps out of circuit and tested them. C115 was the culprit, leaking at only 50 volts. It's supposed to be a 1000-volt cap. I also replaced a couple out of tolerance resistors, nothing too crazy. Two 82K caps were both showing 91k. I'm back to having a running CTC-5 although I'm dreading a full convergence alignment. The sides are really bad. -- Matt Davala |
|
#2
|
||||
|
||||
|
The convergence of my CTC5 wasn't bad once I read and followed the CTC5 service manual. The convergence process is somewhat different from later sets.
I have been able to achieve good overall convergence but it takes patience. Also be aware of the general complaint of low high voltage. To get a bit higher voltage and improve regulation, I replaced the HV rectifier with a solid state 3A3. |
![]() |