Videokarma.org

Go Back   Videokarma.org TV - Video - Vintage Television & Radio Forums > Solid State CRT Televisions

Notices

We appreciate your help

in keeping this site going.
Reply
 
Thread Tools Display Modes
  #1  
Old 06-07-2023, 06:26 AM
Alex KL-1 Alex KL-1 is offline
VideoKarma Member
 
Join Date: Jan 2021
Location: Brazil (Paranį)
Posts: 515
(Now I posted on correct thread):
Only for amusing, I only imagine perhaps a tube-based TV with modern resistors, capacitors and flyback/coils, with nowadays better stable mains, if reliability will be better than in it's days. At least for audio products, with modern parts, I can only need to change tubes when the tube are with problem, and not a problem caused by a bad resistor or (paper) capacitor cooking the tube (in the bias circuits for example). Of course, TV have far more tubes and resulting heat, but even so... (only for illustrating the contribution of passive parts)
__________________
So many projects, so little time...
Reply With Quote
  #2  
Old 06-07-2023, 08:55 AM
JohnCT's Avatar
JohnCT JohnCT is offline
VideoKarma Member
 
Join Date: Jan 2020
Posts: 749
Quote:
Originally Posted by Alex KL-1 View Post
(Now I posted on correct thread):
Only for amusing, I only imagine perhaps a tube-based TV with modern resistors, capacitors and flyback/coils, with nowadays better stable mains, if reliability will be better than in it's days. At least for audio products, with modern parts, I can only need to change tubes when the tube are with problem, and not a problem caused by a bad resistor or (paper) capacitor cooking the tube (in the bias circuits for example). Of course, TV have far more tubes and resulting heat, but even so... (only for illustrating the contribution of passive parts)
Most decent vacuum tube TVs in the 60s and 70s had plastic caps and at least some metal film resistors although I remember some memorable early SS Sylvania chassis that used carbon comp resistors as voltage dropping resistors used to feed low voltage transistors circuits (the resistors got hot, dropped in value, dumped beaucoup volts into low voltage circuits where mayhem would ensue). EDIT: Could have been a hybrid in the D series. In any case, the signal circuits were all SS even if the sweep was hollow state.

Flybacks certainly could have enjoyed modern construction with epoxy and silicone instead of wax, but you would still need large(ish) value high voltage electrolytics which would still be problematic even today given the hours they would run and (as you noted) the ambient tube generated heat they would need to live in.

With regard to mains, vacuum tube equipment is more tolerant that SS stuff to noise and voltage spikes.

A modern built tube TV would definitely be more reliable in many areas compared to vintage stuff, but I'm not sure just how much more reliable a "modern" vacuum tube TV would be.

John

Last edited by JohnCT; 06-07-2023 at 09:12 AM.
Reply With Quote
  #3  
Old 06-07-2023, 09:10 AM
Electronic M's Avatar
Electronic M Electronic M is offline
M is for Memory
 
Join Date: Jan 2011
Location: Pewaukee/Delafield Wi
Posts: 15,496
Quote:
Originally Posted by Alex KL-1 View Post
(Now I posted on correct thread):
Only for amusing, I only imagine perhaps a tube-based TV with modern resistors, capacitors and flyback/coils, with nowadays better stable mains, if reliability will be better than in it's days. At least for audio products, with modern parts, I can only need to change tubes when the tube are with problem, and not a problem caused by a bad resistor or (paper) capacitor cooking the tube (in the bias circuits for example). Of course, TV have far more tubes and resulting heat, but even so... (only for illustrating the contribution of passive parts)
More stable mains?!? They're worse now than I remember them being as a kid. Noise, spikes/dips, outages I seen more of all the last few years than growing up.

The late 60s Zenith's with all film caps, silicone flybacks, and lytics not much different from modern ones (ignoring size) are about as you describe a hypothetical modern set, and are fairly long lived.
__________________
Tom C.

Zenith: The quality stays in EVEN after the name falls off!
What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4
Reply With Quote
  #4  
Old 06-07-2023, 10:21 AM
zeno's Avatar
zeno zeno is offline
VideoKarma Member
 
Join Date: Mar 2013
Location: New Hampshire
Posts: 4,918
IIRC the Sylvania was a D-12. The resistors went between the 250V & 24V.
Caused quite a lot of havoc. Only other shorting resistors I remember were
in GE 18" compactron sets. It was in the video out left rear corner of PCB.
8.2 K 2W IIRC

As far as better tube sets go the first thing I would add is a cooling fan
near the Hoz/HV.

73 Zeno
LFOD !
Reply With Quote
  #5  
Old 06-08-2023, 08:59 AM
JohnCT's Avatar
JohnCT JohnCT is offline
VideoKarma Member
 
Join Date: Jan 2020
Posts: 749
Quote:
Originally Posted by zeno View Post
IIRC the Sylvania was a D-12. The resistors went between the 250V & 24V.
Caused quite a lot of havoc.
Yep, D-12 rings a bell. I was a young shaver when those came out.

John

EDIT: These came out in the late 60s, so I was NOT shaving yet!!!

Last edited by JohnCT; 06-08-2023 at 09:19 AM.
Reply With Quote
Audiokarma
  #6  
Old 06-07-2023, 12:28 PM
Alex KL-1 Alex KL-1 is offline
VideoKarma Member
 
Join Date: Jan 2021
Location: Brazil (Paranį)
Posts: 515
Quote:
Originally Posted by Electronic M View Post
More stable mains?!? They're worse now than I remember them being as a kid. Noise, spikes/dips, outages I seen more of all the last few years than growing up.

The late 60s Zenith's with all film caps, silicone flybacks, and lytics not much different from modern ones (ignoring size) are about as you describe a hypothetical modern set, and are fairly long lived.
Hehe, spikes and noise... here sometimes a very huge spike occurs in the waveform, making noise in EMI filter, trafos, even in some motors...
And, some years ago, I worked at a transformer factory, with plenty of motor inverters: the mains waveform at that place with full production run are almost a squarewave (with rounded corners...)
Ahh, those modern appliances...
__________________
So many projects, so little time...
Reply With Quote
  #7  
Old 06-08-2023, 09:56 AM
dieseljeep dieseljeep is offline
VideoKarma Member
 
Join Date: Jul 2010
Posts: 7,562
Quote:
Originally Posted by Alex KL-1 View Post
Hehe, spikes and noise... here sometimes a very huge spike occurs in the waveform, making noise in EMI filter, trafos, even in some motors...
And, some years ago, I worked at a transformer factory, with plenty of motor inverters: the mains waveform at that place with full production run are almost a squarewave (with rounded corners...)
Ahh, those modern appliances...
You have to wonder what the waveforms look like using invertors to convert HV DC to 3 phase AC, such is in use today.
Three phase AC Motors have to be a special design to be invertor duty!
Reply With Quote
  #8  
Old 06-08-2023, 10:54 AM
ARC Tech-109 ARC Tech-109 is offline
Retired Batwings Tech
 
Join Date: Jun 2020
Location: Planet Earth
Posts: 612
Quote:
Originally Posted by dieseljeep View Post
You have to wonder what the waveforms look like using invertors to convert HV DC to 3 phase AC, such is in use today.
Three phase AC Motors have to be a special design to be invertor duty!
Has to do with the way the inverter creates the sinewave, its basically a high frequency duty cycle where the "full duty" is the crest of the sinewave and the motors have to be insulated to withstand the sharp spikes. I work at a plastics injection molding plant and run a 1500-ton horizontal press that uses two 500hp inverter driven motors to drive the melt extruder screws, According to the system monitor they take an average of 650 amps at 480V when melting glass infused nylon. Overall the press (Cincinnati-Milacron) takes 2.25 megawatt to run everything... this plant has 39 presses in total the largest being 3300 tons and the smallest takes 72KW. There are a number of reactors in the incoming substation just to smooth the power so it doesn't superimpose the noise on the town feeders.
Some of the presses use a triac based PWM heat control, I've never measured or looked at the plant power but when you duty cycle a 50KW set of heaters it's going to make some noise. The electric bill is $100k/week.
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 02:27 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.