I dont know your level so dont take this wrong !
Primary side ( hot) ground for your meter is the negative end of C011. Use it for measurements on the RIGHT side of the SMPS transformer. The chassis ( cold) ground is the tuner & IF shields, CRT dag etc. The left side of transformer windings are the only cold grounds. The isolator is to feed back the cold B+ to the hot side for a reference voltage to control the PS output. In the olden days we saw quite a few of these. If the transistor was OK we would change the 2 modules & isolator. This fixed almost every one. If you have a variac you can try turning it up & down a bit & see what happens. Enuf fer now Zeno ![]() LFOD ! |