Quote:
Originally Posted by Notimetolooz View Post
CRT pin 2 and V105 (12AU7) pin 6 should be 70V. There is a low DC resistance connecting them so the voltages should be about the same.
V105 pin 8 is connected to -85V through a 47 ohm resistor so that voltage will have to be about the same even if the current is very high. If V105 pin 8 was connected to pin 6 there would be a battle of the voltages (150V being the other) across R124 and R125 that could result in the -38V.
V105 could have a cathode to plate short or there could be a short between pin 6 and 8 on the socket.
One could easily pull V105 and see if pin 2 of the CRT swings positive(indicating shorted V105 cathode to plate). Also if C115 were leaking it could cause the plate and cathode to conduct hard simulating a short. If removal doesn't eliminate the negative voltage on pin 2, then your shorted socket scenario would seem likely.
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 11:59 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.