#1
|
|||
|
|||
|
Update: I swapped out the 2 VDRs with MOVs, one at a time, and then both at same time, and there was no difference in terms of current regulation. At 18KV, current drifts about 20-30 mA as the set runs. Any setting of HV above 18KV creates excessive current.
I read in another thread that "Check the screen voltage on the HOT, if its high its an overload(bad flyback, shorted rectifier, cap, damper)." The screen voltage was high on the HO (measure 190-200v and should be 172) I'm now wondering if the issue may be in the focus divider, as the tripler appears to be OK. |
|
#2
|
||||
|
||||
|
Try a 6U10 if you havnt yet. There is a sleeve on the H hold
pull off & recenter into range. Focus div just a pair of very high meg resistors, new p## is 800-616. Dont see that doing it. Burns or bad focus. Filter cans went but a PIA to get to. Need one of those 2 foot xcelite drivers to pull chassis.Only good test for FBT is totally unload it & ring it. If it has shorted turns usually you can also see distorted waveforms. Other poss is one of the high ohm resistors has drifted up. Gotta unhook one end to be sure, time consuming.... 73 Zeno
|
|
#3
|
|||
|
|||
|
OK, good information. I have subbed the 6U10 prior, but no change. I may go ahead and pick up one of the dividers from Talon.
BTW, check out the waveform now, even after I "undid" my mods ![]() PS I have the extra long driver! Quote:
Last edited by Jon1967us; 06-30-2022 at 11:38 AM. |
![]() |