#8
|
||||
|
||||
|
Thanks for posting a great symptom video. I saw many of these in Best Western Motels and Holiday Inns when on family vacations in the 70s
My $.02 = A cap somewhere on the supply to video amps, just a guess considering its a very odd symptom, usually those are found on a Zenith. Video balanced to drive 3 cathodes (K) and demodulated colors drive each G2 from the 9-89. Looking at G2's and K's on a scope will show a changing video or demodulated color, which may not be the issue. It is the DC baselines of K or G2 drifting along with CRT beam current. In the video, its pretty apparent the Scully scene has a "larger bright area" that could: 1. Trigger a gradual increase in B+ to the green G1 - monitor per Zeno's post 2. Be spark gap in crt socket choked with dust, considering only one color is wonky. 3. Be drop in voltage at green cathode, heater-cathode leakage, heater line is tied to B+ via resistor - monitor per Zeno's post, changes here would be obvious. 4. triggered by HV tied into the brightness limiter, may be a buffer cap ? Ill check my Zenith notes and TAB service manual volume III?, there may be something circled on a schemo, I have loose leaf schematics pulled from service binders that were tossed.
__________________
"When resistors increase in value, they're worthless" -Dave G Last edited by DavGoodlin; 05-10-2022 at 10:18 PM. |
| Thread Tools | |
| Display Modes | |
|
|