Whenever I see 60hz all over a chassis I think ground loop, which can be as simple as how you're hooking the scope into the circuit. For instance not having a good ground very near the end of the probe in the near vicinity of where your taking the measurement. I'm just making a general comment for those following along that may not be aware of that situation. It's more important when the piece of equipment is floating on an isolation transformer.