#1
|
|||
|
|||
|
Quote:
I removed the output transformer completely from the circuit and took voltage readings and I'm getting 0V now at pins 1 and 7 of the 5AQ5 tube socket and pin 2 around 5V on the cathode and and still getting 22V on pins 5 and 6 of the 5AQ5 tube socket. The -22V figure came in because of the fact that for some reason or another when I take voltage measurements on anything after C50 all the voltages are negative unless I flip my probes so that I use my positive probe as the negative probe and the negative probe as my positve probe and then I get positive voltage readings, and my reference to ground is the chassis because that's what its supposed to be according to the schematic. |
|
#2
|
||||
|
||||
|
Quote:
I'd like to suggest we focus only on this little section instead of jumping all over the map. C50 is only a audio coupling cap that passes audio from the detector stage to the volume control, so we're really not worried about anything other than this little portion of the schematic. Once we figure out what's ailing the audio output then we can move onto the bigger picture.
Last edited by Kevin Kuehn; 12-07-2021 at 07:43 PM. |
|
#3
|
||||
|
||||
|
For our OP I sketched over the schematic using conventional current the direction DC flows from B+ through the circuit and returns to ground. The 5AQ5 being self (cathode) biased sets the tubes quiescent current. Under normal operation there should be no DC flowing in the volume control or grid circuit. C50 is the grid coupling cap that's purpose it to isolate the 5AQ5 grid from the preceding plate circuit's DC. C51 basically damps out very high frequencies in the output trans primary. It's this flow of quiescent DC current that produces the appropriate voltage drops across the resistance or impedance of the various components. Healthy capacitors should not pass DC therefore would not change this quiescent or idling current in the circuit. You could remove C50 and 51 and the circuit should still work completely isolated from the rest the TV. Normally if you touch a screwdriver or finger to the grid or volume control it will produce a buzz in the speaker. Anyhow I though it might help remove some of the mystery surrounding how this little section of the TV works. Once you understand what's suppose to happen it sometimes helps to find the source of trouble.
|
|
#4
|
|||
|
|||
|
Quote:
OK so what I mean by the voltages after C50 are all Negative is that part of the B+ (245V supply) line goes into TS8-4 which is also where one side of C50 goes in at as well as R54 and R56 and C3B tie in at, and at TS8-3 which is where the other side of C50 comes out (and also where the other side of the 245V supply comes out to supply the 5AQ5 tube with its necessary voltages) is where all of the voltages end up measuring negative, as for my B- reference its where the black wire coming from the power switch ties to the chassis and to the "chassis ground" for the old C3 can (which is out of circuit), and using that B- reference point is giving me negative voltage readings on the TS8-3 side of C50/245V supply line unless I reverse my probes (positive red probe to B- reference and the black negative probe to the voltage reference point). Now I don't know how I can make that any clearer than that but I'm telling you that's what's happening to me with this TV. |
|
#5
|
|||
|
|||
|
I don't know how you could of missed this, but C50 has a lot more to do with the audio output circuit than you think it does, for example the 245V B+ supply is shared in common between the Audio Detector Tube and the Audio Output tube, and both supplies are filtered through C3B which are their common tie point in the 245V B+ supply through R54 and R56 (R54 feeds the 245V B+ supply line to the Detector Tube and R56 feeds the 245V B+ supply to the output tube and both of those resistors are tied to the positive side of C3B which is tied to chassis ground just like it was originally when it was in the old can cap, if you look at my schematic excerpt and my markings explaining where the negative voltages are being measured at and where the common points are in the two "unrelated circuits" you'll see that I'm not nuts in how I'm following this circuit layout and what I mean by the voltages after C50 are negative unless I reverse my leads.
|
| Audiokarma |
|
#6
|
||||
|
||||
|
Quote:
Last edited by Kevin Kuehn; 12-08-2021 at 02:14 AM. |
|
#7
|
|||
|
|||
|
Quote:
|
|
#8
|
||||
|
||||
|
Quote:
|
|
#9
|
||||
|
||||
|
Quote:
|
|
#10
|
|||
|
|||
|
Quote:
|
| Audiokarma |
![]() |
| Thread Tools | |
| Display Modes | |
|
|