No, it's part of the voltage doubler. Used to get over 200V HT (B+) from a 127V supply.

You can't use an ordinary electrolytic. The results will be messy.

I would use a motor run capacitor such as this: https://www.amazon.co.uk/200uF-Capac.../dp/B07Q7XRV54 I presume that internally this is a pair of electrolytics connected in anti-series as a previous poster has suggested.

Alternatively I'd rewire for a conventional rectifier arrangement and run from a 230V supply. In the UK and Europe this is the easiest answer. In the US you'd need an autotransformer to step up the line voltage from 120V to 230V.

Since the OP is in Spain and the mains voltage there is 230V then if he sticks with the original circuit he would need a 230V to 127V step down transformer.

Historical note: While Europe now universally uses 230V, some European countries used lower voltages in the past. These included Spain and Belgium.
__________________
www.borinsky.co.uk Jeffrey Borinsky www.becg.tv
Reply With Quote
Audiokarma
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 05:15 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.