I got the parts today. I replaced the burnt 1000 ohm resistor off pin 3 of the HV regulator, and the new MOV to replace the VDR that I was hoping was causing the excessive HV. I can't tell if it made any difference. The picture looks the same, the HV is 27-28kv with the bright/cont all the way up, and still buries the needle (32+ kv) on my probe with bright/cont all the way down.

I got the HV adjustment pot to turn, and it only varies by 1kv from one end to the other with bright/cont all the way up. No change when the probe is maxed out at 32kv.

When I first powered it up, as soon as the HV came up, there was a SNAP and a flash of light from behind, but I didn't see where it came from since I was looking at the screen. I shut it off, got the camera rolling and turned it back on but it didn't do it again. Maybe something was crabby in the HV cage, the cover is still off.

So I'm stuck again.
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 01:41 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.