Videokarma.org

Go Back   Videokarma.org TV - Video - Vintage Television & Radio Forums > Vintage TV & Radio Tech Forum

Notices

We appreciate your help

in keeping this site going.
Reply
 
Thread Tools Display Modes
  #1  
Old 08-18-2019, 09:41 AM
zeno's Avatar
zeno zeno is offline
VideoKarma Member
 
Join Date: Mar 2013
Location: New Hampshire
Posts: 4,918
+1
What usually happens is the thermistor falls apart then the glowbar melts
down. Numbers I remember were FR922 & FRTV2 IIRC. And yes be sure the coil didnt get pinched !
73 Zeno
LFOD !

Quote:
Originally Posted by damen View Post
Similar RCA circuits used a 107191 thermistor (about the size of a nickel) and a 116534 or 114014 varistor ( the rubber coated looking one). Since this happened after the CRT was changed, be sure the degaussing coil isn't shorting out to the mounting hardware or you'll burn up the new parts.
Reply With Quote
  #2  
Old 09-21-2019, 12:12 PM
Tim Tress Tim Tress is offline
VideoKarma Member
 
Join Date: Feb 2015
Location: Beaver Falls, Pennsylvania
Posts: 109
Workman used to sell both the thermistor and varistor in one package; that was a very common repair in the old days