#1
|
||||
|
||||
|
Quote:
![]() I just went down the Automatic Gain Control rabbit hole, I love learning about this stuff but much of it is over my head. Also I'm not sure I would be able to tell if the image is too grainy, most things are pretty grainy over RF. ![]() If you have some direction as to where I should look let me know. There are lots of pots and I'm a little nervous to just start poking around.
|
|
#2
|
|||
|
|||
|
Quote:
Last edited by TUD1; 11-20-2026 at 08:39 PM. |
|
#3
|
||||
|
||||
|
Looks like you have the early version under run 401.
IIRC one cap behind the h out ( shown), one or 2 on the flyback transformer & 2 or 3 on the bottom chassis. If they are all orange no worries. The white ones open. When they do the HV goes up apx 1.5 KV for each one opened. If it had the 4 lead cap it would be wire tied to the heat sink & is much bigger than the 22-5001. These caps cost Zenith millions. They had to recall about a year of sets. Thats about 20% of 17, 19, 23 & 25 inch sets sold in the US. 73 Zeno ![]() LFOD ! |
![]() |