#14
|
||||
|
||||
|
Quote:
Best options: 1) Get yourself an AC line conditioner ($$$$) I use a Sola, but mostly for line regulation (132V at my outlets.....yes, too high, right off the tranny outside.) It filters out everything but >400msec surges. Pricey items - got mine surplus for pennies. 2) Build your own EMI filter ($) Use an IEC EMI input filter, and a wall outlet output. I made one back in 2002ish for a Navy need. Be sure to carry the ground to a common point. IEC filter: https://www.google.com/search?q=emi+...w=1280&bih=834 3) Buy a TDK or Murata (may be sold under KEC as well) EMI Filter - used ($), new ($$). We used the TDKs on computers - the dot matrix machines we had (22" platen) would generate all sorts of noise on one phase of the line. The TDKs are only rated for 6 or 8 amps, plenty for a TV. The Muratas are larger and harder to find anymore. Schaffner may make some standalones like the TDKs. The X10 Home control system also offered one - it used to be available at RadioShack, good for 5A, and $20 or so. Check eBay. Other tips - use quality coax from Belden/Alpha or Channel Master. Most of the discount store stuff is cheapo 40% coverage - you want >90% coverage, which is braid AND shield foil. Try plugging the TV into an outlet that is off a different leg than the other items. Tough to figure out if you don't have the means to trace the circuit from the panel to the outlet.
__________________
Brian USN RET 22YRS (Avionics/Cal) CET-Consumer Repair and Avionics ('88) "Capacitor Cosmetologist since '79" When fuses go to work, they quit! |
| Thread Tools | |