I cleaned all the pots with deoxit, rotated each 20 times end to end as usual. While observing the bendy picture (normal raster) the AGC control had the usual effect: at CCW end blank raster, picture and sound suddenly appear at 1/3 rotation, getting normal contrast at 2/3 and even more bending-overload at full CW.

What does not add up is that while I had the meter on the AGC tube plate, rotation of the control varied the voltage and only AFTER doing that and then looking at the screen instead of the meter, the picture was close to normal and then horz and vert lock were excellent over the range of the hold controls.

Ill see what happens after I replace the focus resistor - a clearer picture may indicate remaining issues. I actually want the trouble to reappear WHILE the chassis is on the bench and not back in and all buttoned up.
__________________
"When resistors increase in value, they're worthless"
-Dave G

Last edited by DavGoodlin; 03-21-2017 at 01:20 PM. Reason: removed dbl negative "not"
Reply With Quote
Audiokarma
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 10:11 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.