#1
|
|||
|
|||
|
I would not every use a tube tester on:
Damper/horz out/HV rec/shunt or regulator tube. If you are having any HV issues it best to try subbing known working tubes in those areas. I don't think most tube testers can simulate the working environment of a tube, esp those. I pretty much only rely on the shorts test before installing any new tube just to make sure it does not damage the set being worked on. |
|
#2
|
||||
|
||||
|
Quote:
*That first replacement lasted ~3 hours putting out around 15KV before it died. The tester showed it as usable when it sort of worked and dead after it died....Hard to accurately test a tube for future life. I'm used to NOS tubes being DOA, or healthy, but I'm not used to them acting healthy and dying rapidly when put into service. I've got a issue with the color dropping out that I want to fix so I'm going to put some hours on it before I button it up...There could be some secondary issue killing HV rects.
__________________
Tom C. Zenith: The quality stays in EVEN after the name falls off! What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4 |
![]() |
| Thread Tools | |