More on the tint pulling. I have noticed for some time that the set wanted 120vac to make full width. I finally paid attention, and watched it come on today, and saw that the right side was a bit compressed and gradually filled out in a few seconds as things warmed up.
I have a couple of replacement horizontal output tubes I bought a while ago just in case. Substituting one restored full width with line voltage down to 110v. I also think it may have fixed the burst gate pulse, as I don't see the tint pulling (but have to look a while longer in case I'm just not watching the right material to see it).
When I pulled off the plate connector, the plate cap came with it. Had to pry it out of the connector with pliers. Now it has been sprayed with De-Oxit, so hopefully this won't happen again.