#1
|
|||
|
|||
|
The focus looks ok to me. Your scan lines look focused. The video signal looks smeared and weak.
|
|
#2
|
||||
|
||||
|
I always liked that RCA model. It's uncommon and almost looks pre-war, especially with the radio dial.
Lately I've noticed that many of the controls on my sets, both radios and TV's, are really becoming touchy. Much more so than years back. These sets are 70-80 years old now and I guess it should be expected. Good luck with the restoration. |
|
#3
|
|||
|
|||
|
I would first check continuity of all peaking coils in the video chain downstream of the vid.detector.
|
|
#4
|
||||
|
||||
|
Ok I'll start looking there...thanks!
|
|
#5
|
|||
|
|||
|
Do you have a source of raw video that you could inject right after the vid.detector? That would determine if the fault lies downstream or upstream of the v.detector. When localizing this kind of problem, think of the vid.detector as the "continental divide".
Granted, at first glance it looks like something in the IF strip is severely out of whack. But the same visual effect can be caused by an open peaking coil or even a resistor 'downstream' in the video chain. |
| Audiokarma |
![]() |
| Thread Tools | |
| Display Modes | |
|
|