OK, we are dealing with a 21EAP4. Looking at voltages:
B+ = 273, should be 290 Pins 2&6 of CRT, 405 should be 420 pin 7 of CRT, 27 should be 35 Filament = 2.28VAC HV = 14.4kV, should be between 14 and 15.5kV e I do hear some crackling/popping down in the well of the HV rectifier. Should get some dielectric grease in there. Not sure what my HV probe is good for voltage-wise but its a foot long and has creepage disks near the handle so it is good enough for this. Looking at the voltages, they all seem close enough. One thing is that the line going to the CRT plate (pin 7) has an RF choke and it appears to be inline under some plastic tubing. It looks like it may have gotten hot. And the contact was corroded, did what I could for it. Another thing, I had to substitute 3*1200pF caps in parallel for a 3900pF for C42. The idiot that does the ordering around here (me) screwed up and ordered 0.039 instead. Don't think that would make much of a difference though. So, I am leaning towards a weak picture tube. I am going to have to buy a tester, maybe I'll go post a want in the classifieds. Here is a shot of Peter Gunn. Jonathan |