This is very odd.

The tube(s) and camera produce a good picture apart from the spot, so all tube voltages, scans, etc must be OK.

The newer Bi-Alkali IO works ok, no spot, resolution a bit down but o/wise OK.

The older soda glass target tubes have the spot which brings me back to my first thought that is is a tube fault, even thought several different tubes have been tried.

next step might be to try a known good tube tested in different camera, and to try your tubes in the other camera.

As an aside:-

I am told that IO tubes, and for that matter other high vacuum devices, have a failure mode were natural helium in the air "seeing the vacuum in the tube" goes though the glass as the helium is so small. The helium then accumulates in the tube.

If anyone can confirm or deny this I would be interested to hear what is said.
__________________
Regards Brian

Visit the Virtual Broadcast TV camera Museum
Reply With Quote
  #2  
Old 07-20-2016, 04:21 PM
old_tv_nut's Avatar
old_tv_nut old_tv_nut is offline
See yourself on Color TV!
 
Join Date: Jul 2004
Location: Rancho Sahuarita
Posts: 7,815
Quote:
Originally Posted by BrianSummers View Post
...
The tube(s) and camera produce a good picture apart from the spot, so all tube voltages, scans, etc must be OK.
...
I wouldn't be so sure. I would think the multiplier focus should have an optimum value, and get worse on either side. The description says the spot goes "out of focus" (blends across the image) at one end of the adjustment - it seems to me this is the desired condition and should happen near the center of the control range (unless, of course, the picture is degraded).

Question: when showing a picture, does the picture itself (not the spot) get better or worse (dimmer or less contrast) when the spot is prominent or when it's spread out, or does it stay the same?
__________________
www.bretl.com
Old TV literature, New York World's Fair, and other miscellany
Reply With Quote
  #3  
Old 07-20-2016, 05:37 PM
N2IXK's Avatar
N2IXK N2IXK is offline
Technohippie
 
Join Date: Apr 2011
Location: Sittin' on the "Group W" bench...
Posts: 817
Quote:
Originally Posted by BrianSummers View Post

I am told that IO tubes, and for that matter other high vacuum devices, have a failure mode were natural helium in the air "seeing the vacuum in the tube" goes though the glass as the helium is so small. The helium then accumulates in the tube.

If anyone can confirm or deny this I would be interested to hear what is said.
Certainly possible, assuming you ran the tube in a helium-rich atmosphere.

This is the principle behind the helium leak detectors used on high vacuum systems. Helium atoms being able to diffuse through tiny cracks is certainly true. It often happened with early He/Ne laser tubes, but in the other direction, where the He slowly diffused out of the tube (through the epoxy seals), depleting the mixture of Helium until the laser stopped lasing.

A coworker once was able to rejuvenate one of those tubes by placing it in a chamber of pressurized helium for a while.

Some high speed counter (dekatron) tubes that included H2 or He in the gas mix were prone to issues as well.
Reply With Quote
  #4  
Old 07-20-2016, 07:00 PM
old_tv_nut's Avatar
old_tv_nut old_tv_nut is offline
See yourself on Color TV!
 
Join Date: Jul 2004
Location: Rancho Sahuarita
Posts: 7,815
Quote:
Originally Posted by N2IXK View Post
Certainly possible, assuming you ran the tube in a helium-rich atmosphere.

This is the principle behind the helium leak detectors used on high vacuum systems. Helium atoms being able to diffuse through tiny cracks is certainly true. It often happened with early He/Ne laser tubes, but in the other direction, where the He slowly diffused out of the tube (through the epoxy seals), depleting the mixture of Helium until the laser stopped lasing.

A coworker once was able to rejuvenate one of those tubes by placing it in a chamber of pressurized helium for a while.

Some high speed counter (dekatron) tubes that included H2 or He in the gas mix were prone to issues as well.
This is interesting. When we got our first high-def Saticon cameras, we were warned to fire them up for a while at least once every few months to get rid of accumulated gas. I never heard an explanation of where the gas comes from. Also, I'm guessing the cathodes in camera tubes were more susceptible to degradation due to being so small.
__________________
www.bretl.com
Old TV literature, New York World's Fair, and other miscellany
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 01:57 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.