#1
|
||||
|
||||
|
Well I replaced the electrolytics and get a brief raster before a 10uf 450v electrolyric gets hot and kills the raster. I'm going to find the schematic and see what's going on here. This section if a 4 section electrolyric goes to the height control.
|
|
#2
|
|||
|
|||
|
Quote:
|
|
#3
|
||||
|
||||
|
Well that cap keeps getting way too hot and the 33k resistor with it keeps getting hot and opening. While it lasts, the picture looks good, the width bounces from the right and shrinks back and forth.. Any ideas why?
|
|
#4
|
||||
|
||||
|
About the only things that makes an electrolytic get hot are leakage current, installed backwards, or AC across it. You checked the damper tube?
|
|
#5
|
||||
|
||||
|
The electrolyric is in right and the damper tests good. Another collector mentioned shorted windings in the yoke may cause this?
|
| Audiokarma |
|
#6
|
||||
|
||||
|
What's the model number/schematic for this set? I'm curious to take a peek at this circuit.
Last edited by Kevin Kuehn; 05-11-2016 at 04:02 PM. |
![]() |