Old 10-21-2015, 10:55 PM
WISCOJIM WISCOJIM is offline
VideoKarma Member
 
Join Date: Sep 2005
Location: Grand Chute, Wisconsin
Posts: 2,508
Teamwork. I like that!

Only 2-1/2 weeks to the next WARCI swap. See you guys then.

.
Reply With Quote
  #2  
Old 10-22-2015, 03:09 AM
Arcanine's Avatar
Arcanine Arcanine is offline
VideoKarma Member
 
Join Date: Jan 2015
Location: Lake Geneva, Wisconsin
Posts: 281
It may have been suffering low HV before, but no longer. The new focus rectifier, and the shuffling of tubes... And I also cleaned up some dust build up inside the HV cup on top of the flyback box since there was some arcing in there, and I also changed out the anode lead to the CRT with a 50kV rated wire from an old computer monitor, which took care of all the arcing, and makes a nice connection to the CRT, as well.

(and a minor adjustment to my meter so the needle would stop sticking)



25kV! Now, the Hi-Volt adjust is cranked open all the way, so that could be something else, time will tell once it gets more issues, and caps changed.

Now for everything else. One step at a time. This was a big step for me, very excited to see color, 25kV on the meter, and a bright stable image. This will be a nice set again soon!

Last edited by Arcanine; 10-22-2015 at 03:14 AM.
Reply With Quote
  #3  
Old 10-25-2015, 09:17 PM
Findm-Keepm's Avatar
Findm-Keepm Findm-Keepm is offline
Followin' the Rules...
 
Join Date: Jun 2007
Posts: 2,857
Quote:
Originally Posted by Arcanine View Post
It may have been suffering low HV before, but no longer. The new focus rectifier, and the shuffling of tubes... And I also cleaned up some dust build up inside the HV cup on top of the flyback box since there was some arcing in there, and I also changed out the anode lead to the CRT with a 50kV rated wire from an old computer monitor, which took care of all the arcing, and makes a nice connection to the CRT, as well.

(and a minor adjustment to my meter so the needle would stop sticking)



25kV! Now, the Hi-Volt adjust is cranked open all the way, so that could be something else, time will tell once it gets more issues, and caps changed.

Now for everything else. One step at a time. This was a big step for me, very excited to see color, 25kV on the meter, and a bright stable image. This will be a nice set again soon!
Be careful with the HV and a bad/low output focus rectifier. Folks see low HV, crank up the HV, and then have out of focus pix, so they replace the focus rectifier tube or diode, and now they have too much HV, and too much focus current - it smokes the focus coil on these old sets (happened to my CTC16) - it's a no wonder the focus coils were QT parts.
__________________
Brian
USN RET 22YRS (Avionics/Cal)
CET-Consumer Repair and Avionics ('88)
"Capacitor Cosmetologist since '79"

When fuses go to work, they quit!
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 09:15 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.