#11
|
|||
|
|||
|
Okay, just measured the voltages for the 12HL7 tube. The gap in the tube socket is at the 12 o'clock position, so I took the measurements starting clockwise. Positive lead of multimeter connected to tube pin and negative to chassis frame:
Pin 1: 0 volts. Pin 2: 355 volts on startup, dropping to 305 after warm up. Pin 3: 355 volts, dropping to 320 Pin 4:50mV building up to ~150 mV before dropping back to zero and climbing again. Pin 5: Much the same, gets to about 200mV, then drops back to 0 and starts climbing again. Pin 6: fluctuating readings, but never leaving the mV range. (maybe 200 mV max.) Pin 7: Same as Pin 5 Pin 8: started out at 4.2 volts positive, then went to negative 13 volts after warm up Pin 9: Same as Pin 5 and 7 |