Old 09-23-2015, 07:08 AM
Username1's Avatar
Username1 Username1 is offline
Not sure how I got here.
 
Join Date: Dec 2009
Location: Orange County NY
Posts: 3,668
Quote:
Originally Posted by earlyfilm View Post
Yep!

Simply stated, think of it as the gas allows the control grid to go too positive and this makes the tube conduct too much current and shift the grid cut-off-point.


I was always taught that once a tube gets gassy, it will only get worse.

True then, but not always true now, when one tests an old tube that has not been used for 50 years. The heat from the filament can, over several hours or days running, actually improve emission and reduce gas.

James

Tubes generally do not have current flow at the control grid. It is a control
point of a near perfect infinite impedance amplifier. Typically -7 volts DC bias
at G1 to the cathode. It's always one of the first, and easiest checks to see
if a tube circuit has a problem. Plate, Cathode, and G1, should typically have
a reasonable range to them. I never looked into what the "gas" was, and
what it did. Since 'early film' has a description of how the tube testers check
for a leakage current at the G1, it would seem that as the tube ages some
gas is developed inside the tube and behaves like neon or some other non
inert gas would at voltage. It begins to conduct. So it would allow an
unexplainable shift in G1 bias. You may see it there...

I was also always taught that gas will always get worse, and never get better.

If something is turned off 50 years and it gets better with use, I would assume
it is because the cathode gets waken up and it's emissions get better with
time because it's getting back into the heat - reheat cycle - the environment
it was designed to be operating in....

I would imagine the gas condition to be an out-gas of materials used inside the
tube that time and heat, and high current have produced, and once this occurs
it generally can't be undone....

.
__________________
Yes you can call me "Squirrel boy"
Reply With Quote
  #2  
Old 09-23-2015, 01:00 PM
Electronic M's Avatar
Electronic M Electronic M is offline
M is for Memory
 
Join Date: Jan 2011
Location: Pewaukee/Delafield Wi
Posts: 15,496
Quote:
Originally Posted by Username1 View Post
Tubes generally do not have current flow at the control grid. It is a control
point of a near perfect infinite impedance amplifier. Typically -7 volts DC bias
at G1 to the cathode. It's always one of the first, and easiest checks to see
if a tube circuit has a problem. Plate, Cathode, and G1, should typically have
a reasonable range to them. I never looked into what the "gas" was, and
what it did. Since 'early film' has a description of how the tube testers check
for a leakage current at the G1, it would seem that as the tube ages some
gas is developed inside the tube and behaves like neon or some other non
inert gas would at voltage. It begins to conduct. So it would allow an
unexplainable shift in G1 bias. You may see it there...

I was also always taught that gas will always get worse, and never get better.

If something is turned off 50 years and it gets better with use, I would assume
it is because the cathode gets waken up and it's emissions get better with
time because it's getting back into the heat - reheat cycle - the environment
it was designed to be operating in....

I would imagine the gas condition to be an out-gas of materials used inside the
tube that time and heat, and high current have produced, and once this occurs
it generally can't be undone....

.
The Getther is there to collect that out-gasing. If a tube has sat stagnant for decades and the gas has collected away from the getther then running it/ heating it (which will increase the kinetic energy and motion of the gas atoms) may move them into contact with the getther and cause them to be absorbed.

A tube that has been in regular use (as in a tube in a set that a service tech would have see in say the 50's) that has gas probably has a used up getther or a leak too large for the getther to deal with and likely would not improve with use.
__________________
Tom C.

Zenith: The quality stays in EVEN after the name falls off!
What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4
Reply With Quote
  #3  
Old 09-23-2015, 02:17 PM
earlyfilm's Avatar
earlyfilm earlyfilm is offline
Eternal Member
 
Join Date: Jun 2011
Location: Culpeper, VA
Posts: 527
I was defining "gas" as the tube tester defines it, something that causes static charges, almost always positive, to form on a disconnected element.

This usually is not a problem on an amplifier, but on a detector (AGC keying, Sync Sep, AM audio detection, etc.) that has a sharp cutoff, that small change is often a problem.

Squirrel Boy's cathode and Electronic M's getter & getter splatter are the most probable two things that a little heat cures.

James
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 06:07 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.