If you are getting 300, 265 and 115 volts on three points that are directly connected together with wire, then look for bad solder joints connecting them, and open or high resistance interconnect wire.

Look for heater to cathode shorts in tubes as well. Some sets float the cathodes at a variety of voltages, and if the heater line shorts to two cathodes, or is resistively pulled to a certain voltage and a cathode shorts to it, then all manner of havoc can occur....If you find a tube with a H-K short be sure to look up the max heater to cathode voltage in the tube data sheet, and check that voltage in set set to ensure it is not exceeded.

I wish I had enough sam's to be able to pull the one for any given set and follow along, but I don't.
__________________
Tom C.

Zenith: The quality stays in EVEN after the name falls off!
What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 06:22 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.