#1
|
||||
|
||||
|
OK this is from the G line manual.
It calls for a 95-3172-01 so may be different. primary grey & grey brown 3.3 ohm sec #1 black & black green 8.8 ohm for DGS sec #2 blue & yellow filament 6.3 V 840ma sec #3 white & black yellow 3.5mfd cap only red yellow tap to ground red black 135V green 35V green 35V brown 6V red 135V 73 Zeno
|
|
#2
|
||||
|
||||
|
Quote:
Cheers,
__________________
Brian USN RET 22YRS (Avionics/Cal) CET-Consumer Repair and Avionics ('88) "Capacitor Cosmetologist since '79" When fuses go to work, they quit! |
|
#3
|
|||
|
|||
|
Thanks you to everyone who helped me identify the leads of the Zenith
95-3172 transformer. Those resistance readings, made all the difference. I tested the transformer without an oil cap and the HV 135v lead only read 100-103vac. When connected the oil cap the transformer voltages came right up specs. Ed |
![]() |
| Thread Tools | |
| Display Modes | |
|
|