Thread Tools | Display Modes |
|
|
|
#1
|
||||
|
||||
|
Was the horizontal output SS? 30V*4A=120W! the average HO Tube is rated for <20W IIRC, so if it was tube I can't imagine how the horizontal stage could supply that...For more than a few seconds.
__________________
Tom C. Zenith: The quality stays in EVEN after the name falls off! What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4 |
|
#2
|
|||
|
|||
|
Quote:
Also--a Line O/P valve is used as a switch--not in a linear mode, therefore dissipation in the valve is lower than one would expect,--bit like when they are used for RF work--you can push a 6KD6 to produce 200W or more of RF energy, same principle applies--the valve is still within its ratings as its used as a switch, the tuned circuit does the rest..... --Even so though, its a bit mad when you think of it! --The daft things we do in our youth--I would Never do anything like that now--That thing really was a fire-hazard thinking back..... Last edited by Alastair E; 12-04-2014 at 07:53 PM. |
|
#3
|
||||
|
||||
|
Quote:
__________________
Tom C. Zenith: The quality stays in EVEN after the name falls off! What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4 |
![]() |