#1
|
|||
|
|||
|
Thanks Ed .I will check the traces .Everything is cold where the 12volts are going through.I like to know how and what switches the power on.
The next step is to pull out the 2SB1187 and test it.The 5 volt regulator checked fine after I pulled it and tested it. Yes I agree The 800 band thing is over.What they are worried about and they are going under anyway. |
|
#2
|
||||
|
||||
|
With the momentary contact Power button it probably has to have a standby +5V (?) going to the syscon IC, and that would probably have an output that turns on the rest of it. Just guessing! All my RS scanners, I have several, 2050, 2041, 2039, have a power switch on the volume control.
|
|
#3
|
|||
|
|||
|
Thats how I figured it out.The digital switching runs through the syscon chip on the display frontend.
Tonight I played around with it and pulled the power transistor in question out and test it. Its the culprit.So I did some cross referencing back and forth with some spare transistors I had in my spare parts collection. I found a transistor close and a bit more on the power ratings and installed it. Whalaa it fired up. I checked the voltages and they look OK.Since I dont have the service manual so I cant determine if they are right on the money. I'll run it for a few hours and feel for heat and let it do the burn in test to make sure it works OK. Since this scanner was my late stepfathers which made it a sentimental value .It made it more special to get it up and running. Thanks Ed for your input. |
|
#4
|
||||
|
||||
|
Congratulations! That deserves two thumbs up!
|
|
#5
|
|||
|
|||
|
Thanks Ed.Today I reprogrammed the freqs back in the memory .
|