Quote:
Originally Posted by Jon A.
Am I right in guessing that bad HV rectifier/regulator tubes will not cause CRT damage like bad safety caps in SS sets?
|
No. Decapitation of the CRT from its neck due to excessive HV was unheard of in tube sets. It occured only in SS sets with the 4-legged "safety" caps.
When the cap failed, it allowed the HV to soar to 50 KV or higher, which exceeded the dialectric strength of the glass. Bleed-through resulted in thermal stress in the glass which sheared off the neck slick as a whistle.
Tube sets could only make 30 - 35 KV when the regulator failed, which wasn't enuff to hurt the glass.
In reading the tube complement of your set, I was hoping to see a HV regulator tube listed. Are you sure there isn't one lurking back there somewhere? If not, the set uses the nefarious feedback regulation setup which was very problematic. Hoping yours is an exception to the rule.