#1
|
||||
|
||||
|
From the D.P. Gumby restoration dept:
Whilst checking voltages in the 5V4-G, I fried my Velleman VM890 DMM. This, of course, is not recommended. A new Fluke 87-V is en-route. Happy Birthday, to Me.
|
|
#2
|
||||
|
||||
|
Bummer, this is why I'm now using a $20 Harbor Freight meter, don't care if it gets fried.
|
|
#3
|
||||
|
||||
|
Quote:
They are the electronic equivalent of Soviet Straff (Punishment) Battalion soldiers being thrown into the fray. Zhukov to Rossokovski: "How many matches did you light today?"
|
|
#4
|
||||
|
||||
|
Back on the 621. While checking around V105, 1st & 2nd Video Amp, I think I caught a recap boo boo.
Stand by. I think I'm close...
|
|
#5
|
||||
|
||||
|
Quote:
__________________
"When resistors increase in value, they're worthless" -Dave G |
| Audiokarma |
|
#6
|
||||
|
||||
|
Tapped into V104 video and V117 (6AT6) 1st Audio.
Got a fair raster, with horizontal tic lines. Picture detail and depth is not good. Barely any audio. Sounds like just the preamp is audible.
Last edited by M3-SRT8; 05-01-2014 at 09:49 AM. |
|
#7
|
|||
|
|||
|
Nice job... |
|
#8
|
||||
|
||||
|
Tapped into the wrong audio junction point. Tapped into the correct point and was rewarded with audio. Good gain, but I have a buzzy, distorted 4 x 6 cone.
After prodding the voice coil by pushing on the center cap, I believe the coil is not blown or rubbing in the gap. Found that part of the cone is detached from the center cap. After masking off the spider with a trimmed piece of paper (see photo) I applied glue (Titebond) to the torn area and applied light pressure to the speaker cap with a rolled up ball of paper towel and a piece of masking tape. I'll let it dry in place overnight. Fingers crossed.
|
![]() |