Quote:
Originally Posted by DaveWM View Post
per Zenith 40-180=-140 overall bias

Per yours 33-190=-157 overall bias

extra -17 v neg bias does not seem like it should be too much, but I don't now that for sure.

the 40 or 33v on G1 is a simple voltage divider of a 390k and 75k resistor connected to the 250v source. if the 390k has drifted up that would reduce the G1 bias.

the 190 is a result of the bias and the load on the output transistors. for that I would look at those resistors on the service setup and maybe the 18k collector load resistors on the output transistors (they go to the 250v source).
I have new 18K and 1.8K resistors for the setup. I got them in case I needed to change them. I tried to test them, but they both come up as 1.6K. I'm sure it's because they share a connection. I'll have to life them and test.
__________________
Pioneer SX-1080, Pioneer PL-115D, Pioneer CT-F9191, Pioneer RG-1, Wollensak 8050A, Akai 4000DS MkII, Pioneer CS-05 & Polk 1.2TL

Denon 5803A, Pioneer DVL-700, Pioneer CT-W603RS, Toshiba HD-A3, D-Link DSM-520, Dish VIP-722, Polk 1.2TL, CSi5, LS/fx, RT-800 and PSW-650
Reply With Quote
Audiokarma
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 11:09 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.