#8
|
||||
|
||||
|
It was shrinking horiontally (losing horizontal size as well as severe horizontal
ringing of the raster, not the image) and expanding vertically and getting dim (i.e. losing HV and hence blooming). The horizontal drive, on a scope, was perfectly stable. The waveform at the HOT cathode was showing a current drop and a phase shift. The waveforms on either side of the horizontal linearity coil were changing size and phase and showing odd ringing. None of this depended on presence of signal. What was really odd is that it was working with an open (to an ohmmeter) screen resistor on the HOT. The culprit resistor had at some time gotten very hot, as its markings were obliterated. Doug McDonald Last edited by dtvmcdonald; 05-24-2013 at 07:40 AM. |