#1
|
|||
|
|||
|
after replacing all the wax paper caps, I disconnected the can caps from the circuit (did not remove them from the chassis, just disconnected the terminals), and then used a vintage eye tube type cap tester. I started out on the lowest voltage leak test (25v IIRC) and would fix the test knob so the voltage would stay applied for an extended period. Most of the sections tested shorted (eye would not open), but over time the eye would open, when it did I would switch to the next higher voltage and repeat the process until the eye would fully open at the rated voltage.
I do not think the process would have worked as well if I had just used a variac for a lot of reasons that I don't want to take the time to document. Variacs are useful tools but not for reforming. Note, I am not saying this technique will always work or if it works how long the caps may last. In fact if I was repairing the set for someone I would not even bother, rather I would prob just put in new caps, it would be faster and prob safer, but I like to experiment and that was what this one was about. Lastly I always put a fuse on the B+, and size it so it will blow quickly. If SS rectifier is used I will add a thermistor to allow for a fuse that is also just above the max operating current (inrush will blow a fuse too close to max). Fusing should be done regardless of what is done about caps (reform or new), frankly new caps can fail, and in some cases I think a good old can cap may outlast some BS china cap. |
|
#2
|
|||
|
|||
|
Hi All;
Dave can you tell me which Cap tester you have ?? I have a Solar Exam-eter Model CF.. I don't even know IF it works.. And I need to get the manual for it, I found the site the other day, but had ran out of printer paper, from before, so I did not print it.. THANK YOU Marty |
|
#3
|
|||
|
|||
|
Heath kit. Pretty much any old school cap tester should work, just need something that has a leak test that goes up high enough (think mine is 450v tops). Some testers use an eye tube, others a meter, the meter is prob better, I ofter will put a current meter in series with the cap to see exactly how much leakage there is (even with a fully open eye they will leak some). comparing to a new cap gives you an idea of how good an old one is. I recall there is a table somewhere that shows the allowable leakage in mA by capacity.
|
|
#4
|
|||
|
|||
|
Hi Dave;
Good old Heath Kit.. Thank You for the info.. THANK YOU Marty |
![]() |
| Thread Tools | |
| Display Modes | |
|
|