Sorry been busy, and could only wish for more time to work in it. Sigh.
Anyway, I don't know why I made that error on the color code. Maybe it was because I was reading it @ 6 AM. It measured at 134.4k on my 200k scale. Norbert, I did verify the tiny little disc cap was not only connected to the center connection of the blue pot, but also eventually ended up at the 120K resistor. As for a falling solder blob, I doubt it would effect the G2 controls. I did the work with the set on its side, so any blobs would have fallen into other areas of the set. If a new problem occured, that would make sense as a cause. I cannot find the spark gaps... Are they visible from the top of the chassis, or underneath? What purpose do they serve? I'll have to get another meter to read those voltages. Mine only goes to 1000v.
__________________
From Captain Video, 1/4/2007 "It seems that Italian people are very prone to preserve antique stuff." |
|
#2
|
||||
|
||||
|
Quote:
Spark gaps keep some of the CRT electrodes from getting overvoltaged, or to keep stray high voltage from the CRT from overvolting the CRT drive circuits. .
__________________
|
|
#3
|
||||
|
||||
|
Since my meter only goes to 1000v, I used a HV probe just to see if it would read "anything" on either side of the pots. I do, although since both sides appear to move the needle roughly the same amount, I would guess the 1200v side is low?
Still haven't found the spark gaps. I also noticed something about the schematic voltages from the pots to the CRT. The red shows 870v, blue 940v and green 840v. Red being the least efficient phosper, shouldn't it have the highest voltage?
__________________
From Captain Video, 1/4/2007 "It seems that Italian people are very prone to preserve antique stuff." |
|
#4
|
|||
|
|||
|
Sounds like the boost voltage is missing. Check the parts on the flyback board. Maybe the boost diode or resistor popped.
|
|
#5
|
||||
|
||||
|
Quote:
Then I measured the two things that looked like diodes in both polarity directions, using the diode scale on my meter. Both showed open in each direction, so could this be the fault of my meter? The smaller one is wired right to the 27K resistor, so I suppose it's suspect. It is labeled X4 on the schematic, but there is no electrical specification in the diode chart, just a part number. How would I replace this if it is bad? Photo below:
__________________
From Captain Video, 1/4/2007 "It seems that Italian people are very prone to preserve antique stuff." |
| Audiokarma |
|
#6
|
|||
|
|||
|
First, GET THAT SOLID STATE TUBE OUT OF THERE!! and put the right regular tube in there.
You cant test those two diodes with a multimeter. You need to use something that applys in excess of 200volts like an eye type tube tester in the leakage test mode. The smaller of the two diodes is the boost diode. Check with you meter to verify you have boost voltage coming out of it. The long one is focus. BUT, those solid state tubes can cause all kinds of issues like super high voltage. |
|
#7
|
||||
|
||||
|
Quote:
Was this some kind of aftermarket part? Who made them? Why? As for measuring voltage after the boost diode, that requires the cage to be open... Is that allowed by the TV safety gods? I'd hate to have "always seeking better gray scale" on my tombstone.
__________________
From Captain Video, 1/4/2007 "It seems that Italian people are very prone to preserve antique stuff." |
![]() |