turned in on, no pic, HOT is starting to red plate. checked the grid drive, its there but a bit low at -26vdc. No glow on the neon bulb tester at the HOT but a little around the fly. I disconnect the HV rectifier tube and try again, this time I get neon at the HO and see arcing at the tube cap to the plate of the HV rectifier. Its an odd ball a 1DG3 with an odd octal filament base of 3 and 8 not the normal 2 and 7, my mercury tube tester can not test it. Rather than dragging out my hickok 533 and trying to figure out how to configure the switches, i just subbed it, a better test anyway (I happened to have a NOS handy). Bingo HV back. Bugs me that I can't test the tube in the mercury 1000.
why the heck did they have to use such an odd ball tube?
oh rechecked the HOT grid drive for future reference -36v
|