Quote:
Originally Posted by alespn
I'm skeptical about the number of lights the article claims are used. KSD was the first station to go on the air with Image Orthicon cameras as opposed to the Iconoscope. The amount of light needed was a fraction of the 1000+ footcandles required for the Iconoscope. I've got a photo somewhere of their studio and the lights appear to be mostly 1000 watt and 650 watt instruments.
|
Use of five 1000 or 650 watt fixtures per scene area would be reasonable, so maybe that's what the author should have written.
The NAB Handbook 5th Edition (1960) recommends feeder capacity for monochrome of 25 watts per square foot, with on average 50% of that capacity being used. For color, four times the above figures are recommended. This is to provide base light of 75 foot-candles, base plus key of 100 foot candles. Again, the numbers are multiplied by four for color.
So, the 2000 foot-candle level suggested for good iconoscope results with the iris stopped down would imply 250 watts per square foot actually in use. Whew!