I've got some readings on the electrolytics and a better picture of the schematic.

There are 5 multi stage electrolytic capacitors in the set. Towards the top of the picture, just above, and just to the right of the vertical centering control you can see two sections of C116. The negative on this cap reads shorted to ground which according to the schematic is correct. The other four caps are isolated from ground. Coming right off the center tap of the power transformer is the negative leads of C127, C128, and C131. Further along the line you have C132. Rather than give it away, how would I read the schematic and figure out what resistance reading those four caps should have to ground?
Reply With Quote
  #2  
Old 02-06-2012, 12:40 PM
old_coot88 old_coot88 is offline
VideoKarma Member
 
Join Date: Sep 2009
Posts: 2,654
Quote:
Originally Posted by vts1134 View Post
I've got some readings on the electrolytics and a better picture of the schematic.

There are 5 multi stage electrolytic capacitors in the set. Towards the top of the picture, just above, and just to the right of the vertical centering control you can see two sections of C116. The negative on this cap reads shorted to ground which according to the schematic is correct. The other four caps are isolated from ground. Coming right off the center tap of the power transformer is the negative leads of C127, C128, and C131. Further along the line you have C132. Rather than give it away, how would I read the schematic and figure out what resistance reading those four caps should have to ground?
Hmm.. so the power xfmr CT is the negative voltage source*, supplying 110V negative for stuff elsewhere in the chassis. And the main filter for it is the 40mf.cap (square symbol). Can't read it too good, but i b'lieve it's C128A). The positive side of this cap should go to ground. Is this wired correctly? If it's not, the negative supply would have a large ripple on it. So check this first, and then check for ripple. And verify that there's 110V negative on it (+/- 10% or so).

To check resistance of the -110V source to ground, just look for a DC path to the nearest ground symbol in the schematic (hint: it goes thru the ion trap coils), and add up the values of the resistances in that path. And see if the sum agrees with the ohms reading you get on the meter (+/- 10% or so).
------------------------------------------
*This technique is called "back biasing". You'll find it used in old equipment quite often, particularly in 30s radios. The CT of the power xfmr winding, instead of going directly to ground, goes through a chain of resistors or a large tapped resistor to form a voltage divider, supplying negative voltages for biasing other tubes in the set. A Google under "Back bias voltage" should turn up some good info on it.

Last edited by old_coot88; 02-06-2012 at 04:25 PM.
Reply With Quote
  #3  
Old 02-06-2012, 06:40 PM
vts1134's Avatar
vts1134 vts1134 is offline
Looking For Time
 
Join Date: Apr 2011
Location: Pittsburgh, PA
Posts: 1,534
Quote:
Originally Posted by old_coot88 View Post
To check resistance of the -110V source to ground, just look for a DC path to the nearest ground symbol in the schematic (hint: it goes thru the ion trap coils), and add up the values of the resistances in that path. And see if the sum agrees with the ohms reading you get on the meter (+/- 10% or so).
Such an easy answer to my question. Seems silly that I had to ask, but now I know. All of the resistance readings on the negative sides of the capacitors read correctly.

Quote:
Originally Posted by old_coot88 View Post
Hmm.. so the power xfmr CT is the negative voltage source*, supplying 110V negative for stuff elsewhere in the chassis. And the main filter for it is the 40mf.cap (square symbol). Can't read it too good, but i b'lieve it's C128A). The positive side of this cap should go to ground. Is this wired correctly? If it's not, the negative supply would have a large ripple on it. So check this first, and then check for ripple. And verify that there's 110V negative on it (+/- 10% or so).
This is wired correctly, and there is -110v present.
I believe that I am checking for ripple, but perhaps I have the test wrong. I have put my meter on an AC 4v scale. I've connected the ground lead to chassis ground and the probe through a .1mfd cap to negative on C128. Is my test correct, and am I seeing ripple on the meter?
http://www.youtube.com/watch?v=b5BBxQlqp1o
Reply With Quote
  #4  
Old 02-06-2012, 08:40 PM
old_coot88 old_coot88 is offline
VideoKarma Member
 
Join Date: Sep 2009
Posts: 2,654
Yes your hookup is right. It's showing just a little over 2VAC of ripple. That shouldn't be anywhere near enough to cause the huge hum bar effect you're seeing. This pretty well eliminates the negative supply as the source of the problem.

So check for ripple on the positive supply, first on the 'upstream' side of the spkr field* coming out of the rectifier (there'll be a large ripple here) and then on the 'downstream' side (top of C127A). Then at the top of C116B. The ripple should smooth out to just a volt or two and get progressively smoother the further downstream you go, such as at C116A.
-------------------------------------
*The speaker field serves double duty as a filter choke, a common practice in old equipment.
Reply With Quote
  #5  
Old 02-06-2012, 10:08 PM
vts1134's Avatar
vts1134 vts1134 is offline
Looking For Time
 
Join Date: Apr 2011
Location: Pittsburgh, PA
Posts: 1,534
Quote:
Originally Posted by old_coot88 View Post
Check for ripple on the positive supply, first on the 'upstream' side of the spkr field* coming out of the rectifier (there'll be a large ripple here) and then on the 'downstream' side (top of C127A). Then at the top of C116B. The ripple should smooth out to just a volt or two and get progressively smoother the further downstream you go, such as at C116A.
-------------------------------------
*The speaker field serves double duty as a filter choke, a common practice in old equipment.
Yep, this is exactly how the set is behaving. Progressively less AC as I move further downstream. By the time I get to C116A the ripple is less than a volt. A real for sure.
I thought outside the box today and considered that there was outside interference so I unplugged my LED work light transformer and every thing else on my bench to see if the problem was external to no avail.
Reply With Quote
Audiokarma
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments