If there is a short in the high voltage it will kill the regulator transistor. This set uses a buck boost regulator circuit (I hope I remember that right). It is imperative you use isolation when working on that chassis as it is not the run of the mill RCA with a switch mode supply.
Also, the regulator must be well mounted on its heat sink or it will fail rapidly. There are some zener diodes in the power supply that short when the regulator dies.
Some service hints were jumper q4114 source to drain. Use a variac to adjust B+ to 95 volts. If the set turns on, adjust the variac so B+ is 125 volts. If all is well (except ripple in the picture) the power supply is at fault and needs service. Other notes I have are C4153 causes B+ to be about 80 volts and R4116 burns up. Q4116 if shorted causes B+ to be 60 volts with regulator working. C4106 fails, burns out Q4114. Replace with a .47 polyester.
Above all, again, USE ISOLATION TRANSFORMER!
I've repaired a good number of these sets and see mostly the 19 and 25 inch. I like them as they are good performers. They just have their quirks......
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 08:14 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.