yes you can try it with the tube out, just monitor the AC line current going in, and the AC voltage coming out on the secondary. slowly ramp up the voltage, with no filaments to heat up and no plate loads on the B+ the current should be very low, near 0 amps at low voltage, and only a few milliamps at full line voltage. with Tubes in but B+ disconnected (like a popped fuse or circuit breaker on the B+) it should be about 1 amp at full line voltage to power all the filaments. This is where a variac and AC amp meter really pay for themselves.
|